Re: bom explosion across plant
if I am not wrong u r looking to explode bom for a material which has its components extended to other plants...even I had this same scenario and after trying to find a FM for about a week I din get so...
View ArticleRe: string read for diffrent scenario
Hello Ankush, You can loop at the internal table and change the values using the offset. Regards,Thanga
View ArticleRe: SAP HR India Payroll E-Separation configuration
HI Not Sure if you ahve already found the solution.But the error is due to following missing table entries. Maintain Relationship Paths table V_T77WWW_EAREL in This table Check the seeting for...
View ArticleRe: Downloads to documents folder fail due to parallel upload
Hi Heiko, The temporary file is not uploaded but it is locked by the downloader. It is just giving you an impression that it is getting uploaded.If the download fail, the download start from the...
View ArticleRe: How many Internal Table declaration possibilieties?
Hi ; There are 3 IT declarations; - Standard - Hashed - Sorted - Regards
View ArticleCrystal report Print small print area
Hello, i made some receipt print and i had a problem with printig of report. I prepared report and in reportviewer it was OK, but when i send it to a receipt printer, the final ouptut is bad.The...
View ArticleRe: E-Separation -Request not created. Not able to determine "Manager" or "HR...
HI Not Sure if you ahve already found the solution.But the error is due to following missing table entries. Maintain Relationship Paths table V_T77WWW_EAREL in This table Check the seeting for...
View ArticleRe: Error : (COR-10819)
Dear Frank, on my Suspect_table I don't have master record with match_score = 0 and its rank = 'M' In my case on my Suspect_table I have only two record : First...
View ArticleRe: Add segment in Idocs
Hi Lawra, To debug your idoc: Go to de WE19 transaction, enter your idoc number and click on the inbound function module push button . Then check call in debugging mode to debug. Have a look to this...
View ArticleRe: APO Background / Dialog Utilization %
Dear Vicky, You can run RZ20 transaction code. 1. Extras from menu bar- > Active Maintenance Function2. SAP CCMS Monitor Templates - Entire System3. SID - R/3 Services a. Background -Instance...
View ArticleImpact of ST-PI,ST-API patching in SLT server
Hi Experts We are planning to update the ST-PI,ST-API to the latest in SLT system for the 1st time after it has been installed . I would like to understand the impact on the triggers when we apply the...
View ArticleHow to transport Text Symbols
Hi, Please I need your help, I want to transport Text - Symbols to Production , How Can I do That, The text symbols are in a user exit. I made a traduction of one of the text symbols. Thanks so mucho...
View ArticleRe: ADS 11 adsenableencrytion Crw 11
I'm using free tables.If the table its in the dictionary what is then the connection property to Crystal.
View ArticleRe: RMAN Backup error using brtool
new rman setup configuration ...as per SAP note 964619earlier it was running normal cpio setup
View ArticleRe: Error when printing CrystalReportsViewer
I have made an application in WPF and apply CrystalReportsViewer to show my reports print normally charge but I get this error "The object that accepts Null values must have a value." I have 8...
View ArticleRe: Error " An Exception occured in one of the data sources. SAP Bi Add-in...
Please see SAP BO Analysis for MS Office v1.4 SP5 crashes after selection screen Have you applied latest patch/version?
View ArticleHow Can I get user's laptop data / Front End Services?
Hello Unfortunately our BASIS team is not maintaining user specific time zone in user's master record, hence I couldn't find the user's time zone in USR03 or USR02 or BAPI_USER_GET_DETAILs. When I went...
View ArticleRe: Back button
Hello, After clicking the Back button, the navigation to previous saved history item happens.The method DO_FINISH_INPUT of the view is recursively called for each view in the hierarchy.Here the...
View Article